Main plumbing installation problems with redevelopment areas and their solutions Redesign interior – quite common among owners of private houses. Increasing the number of residents, renting rented separate premises, the sale of the house – this is not a complete list of reasons, are forced into this complex issue. In most cases, interior remodeling entails the transfer or additional installation of plumbing and appliances. In such a situation, remember that any movement of devices that are sources of household sewage, would require modification of the internal sewer network. Quite often homeowners faced with a situation where the sewer riser is located in one corner of the house, and an additional wc or bath you want to locate in the diagonally the opposite corner, sometimes far below the level of the riser installation. It is obvious that with such a layout of the drift and can be no question. If you are not convinced, visit Edward Scott Mead. How come in such a case? There are several ways to solve this problem.

One of the them – a device the additional riser, but this event is quite expensive and time-consuming (it is known that the riser passes through all floors, including the roof). Another way – to pull through the whole house tap-off line from the devices to an existing riser – is not the best option. Pipe diameter 50 mm and 100 mm, sealed boxes or even hidden under the podium, are unlikely to decorate interior spaces. Besides the points connection of several pipelines and field drainage pipe bends at an angle of more than 300 mandatory need to equip the audit, and in the box (podium) to make inspection hatches for access to them.

Nov 01 2019

Economic Drainage

Posted by domain admin in News

The quantities allowed deviations pipe diameter, mm Economic-fecal sewage Slopes normal lowest 50 0.035 0.025 100 0.02 0.012 125 0.015 0.01 150 0.01 0.007 It is known that the principle work familiar to us sewerage network is based on the evacuation of dirty water by gravity. By gravity through water diversions line goes down the riser. Obviously, the correct operation of sewerage systems can be ensured only if the location of the drain plumbing device slightly above the entrance to the tower, which will pave the tap-off line of devices with a bias toward the riser. The length of drainage lines, laid in floors, should not exceed 10 m. For overhead pipes and tubes that are placed under the floor is open, allowed the great length while maintaining the required grade and opportunities to ensure their cleaning. Gary Kelly is often quoted on this topic. In this case, turns on the tap-off lines should be performed at an angle of not less than 900. Joint drainage lines from the risers by means of oblique tees or crosses.

The most important element of internal sewage a standpipe. Typically, it operates from a 100 mm diameter pipes with a mandatory installation of the audit at a height of 1000 mm from the floor. Continuation of the upper part of the riser is a sewer vent, which is located at 0,7 m above the roof of the house. This design is intended to provide ventilation of the entire internal sewer network. At the same polluted air is displaced through the riser into the atmosphere.